DUAL ATP CORROSION INHIBITOR INJECTION PACKAGE
Two ATP3 pumps + 250-litre chemical tank
- Dosing rate: selected for each location; final variant duty requires confirmation
- Discharge pressure: final variant duty requires confirmation
- Chemical storage: 250 litres
CheckPoint’s dual ATP corrosion inhibitor injection package combines two electric plunger pumps and a 250-litre chemical tank on one skid. The project supplied nine packages for corrosion inhibitor dosing at individual junction locations.
Pump selection for each location
Each unit uses two CheckPoint ATP3 pumps with ceramic plungers. The project includes 1/4-inch and 3/8-inch plunger variants to suit different duties. Flow and pressure must therefore be checked against the datasheet for the specific package.
The dual-pump layout brings both pumps and the chemical supply together. The final control philosophy determines how the pumps operate. A two-pump arrangement alone does not establish whether they run together or as a duty and standby pair.
Storage and monitoring in one package
The 250-litre tank supplies the injection equipment. The project scope includes level, pressure and flow instrumentation, together with pressure relief valves and pulsation dampeners. These components support chemical inventory checks and monitoring of the injection duty.
Engineering documentation and factory acceptance testing form part of the project scope. Flow and pressure tests provide checks against the specified duty. Commissioning spares and two-year operating spares are also included in the documented scope.
Specify your corrosion inhibitor duty
Contact CheckPoint to discuss a dual ATP corrosion inhibitor injection package. Share the chemical, required flow, line pressure and control requirements so the pump and material selections can be reviewed.