Corrosion Inhibitor Injection Package

One duty pump + one standby pump + chemical tank

  • Chemical dosing rate: 0.826 US gal/h (3.125 L/h)
  • Discharge pressure: 1,500 PSIG (103.42 barg)
  • Tank working volume: 580 litres

CheckPoint’s gas-driven corrosion inhibitor package combines chemical storage, pumping and instrumentation on one skid. Two Series 1250 GR plunger pumps provide one duty pump and one standby pump. Local manual adjustment allows operators to set the required injection rate.

Wellhead gas powers the pumps

The package receives wellhead gas at 1,200 PSIG. A dedicated regulator reduces this to 100 PSIG for pump operation. This is the pump drive supply; it is separate from the chemical discharge pressure of 1,500 PSIG.

The listed chemical dosing rate is 3.125 L/h, or approximately 0.826 US gallons per hour. The standby pump provides an alternative to the duty pump. The operating and changeover procedure should follow the project controls and site requirements.

Chemical storage and monitoring

An integrated SS316 tank provides a working chemical volume of 580 litres. Level indication and monitoring support inventory checks. Each dosing pump uses a 1/4-inch ceramic plunger, a 316 stainless steel head and check components, and FKM packing.

Calibration facilities, flow metering, pressure relief protection and pulsation dampening form part of the skid. Instrument signals terminate at a skid-mounted junction box. The tank, pumps and piping sit on a coated carbon steel frame.

Review your corrosion inhibitor application

Contact CheckPoint to discuss a gas-driven corrosion inhibitor package. Chemical compatibility with the stainless steel, ceramic and FKM components requires client confirmation. Flow, pressure, tank capacity and controls can be reviewed for your site.

Explore our chemical injection pumps.

CheckPoint Pumps & Systems logo

Whether your solution requires a single pumping application or an expansive engineered system,